Cable Voltage Drop Calculator
Calculate voltage drop over a DC cable run from wire gauge, length, and current draw, to check if your power run is safe, live as you type.
Cable
Load
Common for powering lights, monitors, or camera accessories over a long DC run — too much voltage drop can cause dimming, flicker, or devices refusing to power on.
Results
Why Long Power Runs Need a Voltage Drop Check
Every foot of cable has resistance, and that resistance eats into the voltage that actually reaches your light, monitor, or camera accessory at the end of a long run. Undersized cable on a long DC run can cause dimming, flicker, or a device that simply won’t power on — even though the source voltage measures correctly at the supply.
Why It’s a Round-Trip Calculation
Current has to travel down the cable to the load and back through the return conductor, so the resistance of the full circuit is double the one-way cable length. This tool accounts for that automatically — enter the one-way distance to the device and it calculates the round-trip drop correctly.
Reading the Assessment
A voltage drop under 3% is generally considered safe for sensitive equipment. Between 3% and 5% is usually acceptable but worth watching, especially for dimmable LED fixtures that are sensitive to supply voltage. Above 5%, expect visible dimming or flicker, and above 10%, some devices may fail to power on at all — at that point, a heavier gauge cable or a shorter run is worth the tradeoff.
This tool is especially useful for:
- Gaffers and lighting techs running LED fixtures long distances from a battery or distro.
- Video village and monitor setups powered over extended DC runs.
- Anyone choosing cable gauge before a long power run on location.